Pre-power checks: 1) Verify every post connection is correct polarity, fully seated, and torqued. 2) Confirm the STARTER ONLY post has a single cable to the starter and nothing else landed on it. 3) Confirm HMI power and CAN are landed and terminations are complete.

Power-up: 1) Set the SHIPPING DISABLE SWITCH to the enabled (run/ON) position. 2) Perform the System Start-Up Sequence: ensure the Shipping Switch is enabled; press the 48V system power button and wait 5 seconds; press the Starter System button and confirm the green LED ring becomes solid; verify the state of charge on the HMI. 3) Confirm the system is online and error-free on the HMI.

Functional tests: 1) Confirm the HMI shows live state of charge and system data over CAN. 2) Test engine start using the Starter System. 3) Verify alternator charging is recognized when the engine runs — the HMI shows power coming in.

Final installation checklist (sign-off items): Unit mounted, tie-down brackets fastened and mounting rods torqued. OEM ground connected to SYSTEM GROUND. OEM starter lead landed on STARTER ONLY post. STARTER ONLY post isolated, single cable to starter, nothing else landed. Expansion Pack 48V and ground connected (if used). OEM 12V and alternator (via 300A fuse) connected to 12V POSITIVE. HMI 48V power landed on 48V POSITIVE / SYSTEM GROUND. Front panel sense/control connected (vsense, temp+/-). HMI CAN connected and termination verified. Start-up sequence completed and system online on HMI. Engine-start test passed.

Torque specifications (SAE primary, metric in parentheses): Core Power main posts (48V POSITIVE, 12V POSITIVE, SYSTEM GROUND), 5/16 inch — 100 in-lb (11 N-m). STARTER ONLY post (Starter System), 8mm — 71 in-lb (8 N-m). Alternator 300A fuse post, 3/8 inch — 75 in-lb (8.5 N-m). Mounting rod nuts, 1/4-20 — 84 in-lb (9.5 N-m). Tie-down bracket screws, 10-32 — 30 in-lb (3.4 N-m). Note: where a component publishes its own torque (Starter System post, 300A fuse, battery terminal), that value takes precedence.