Installation: overview, compliance & safety
The Installation Manual covers the generic installation of the IdleX Core Power Unit, the optional Expansion Pack, and the HMI Assembly into a heavy truck. It addresses mechanical mounting, electrical connections to the unit's posts and front control panel, and initial commissioning. Operation, monitoring, maintenance, and troubleshooting of the installed system are covered separately in the O&M Manual articles in this category.
A Peterbilt 579 is used as the reference vehicle throughout the manual; your installation may differ, particularly the height-plate spacers described in the mounting article.
Read the entire manual before beginning installation. Installation must comply with all applicable local codes, including but not limited to: United States — NFPA 1192, NFPA 70. Canada — C22.1, CSA Z240.
WARNING: Installation must be performed by qualified personnel familiar with high-current DC systems and the risks involved.
DANGER: Disconnect ALL power sources to the vehicle — starting/house batteries, generator, and shore power — before beginning any installation work.
Recommended overall sequence: install the HMI Assembly first and route its cables, then install the Core Power Unit (and Expansion Pack) in the battery box and make all connections, then commission and test the system.
DANGER: Connect the SYSTEM GROUND (negative) FIRST and disconnect it LAST. Never make or break a live high-current connection.
WARNING: The internal Starter System is an ultracapacitor and can hold a charge even with the unit off. Treat the STARTER ONLY post as energized until verified discharged. Connect the starter cable LAST and verify polarity before connecting.
CAUTION: Verify polarity at every post before connecting. Reverse polarity will damage the unit and can cause severe arcing. Keep the SHIPPING DISABLE SWITCH in the disabled position until commissioning.
Required PPE: safety glasses or face shield, insulated gloves rated for the system voltage, insulated hand tools, and removal of all metal jewellery, watches, and rings before working on the electrical system.