Jump-starting a discharged Core Power Unit

Use this procedure to recover a Core Power Unit that has fully discharged and will not power on. Connect an external 12V donor source (another vehicle, a portable jump pack, or a bench supply) to the 12V POSITIVE (+) and SYSTEM GROUND (-) posts only. This procedure assumes the internal Starter System is also depleted.

1) Confirm the Shipping Switch is enabled.

2) Observing correct polarity, connect the donor positive (red) lead to the 12V POSITIVE (+) post, then to the donor source positive terminal.

3) Connect the donor negative (black) lead to the donor source negative terminal, then to the SYSTEM GROUND (-) post.

4) Allow the unit to accept charge for a few minutes.

5) You should now be able to start the truck like normal. If you have no crank, verify the Starter System is powered on — press the power button on the Starter System and confirm the green LED ring illuminates and becomes solid before attempting a start again.

6) Once the truck is started, wait until the HMI powers on and shows a recovering state of charge.

7) Remove the leads in reverse order: SYSTEM GROUND post first, then the donor connections.

8) If the HMI does not show the 48V system, press the 48V system power button on the front panel and wait 5 seconds for the system to come online.

9) Once the HMI shows a healthy state of charge, you are good to shut off the engine or continue as normal.