IdleX Support

Contact Us

Installation: tools, materials & kit bill of materials

Tools required: drill and bits, including a 9/32 inch (7mm) bit for the 1/4-20 rod clearance holes and an 11/32 inch (9mm) bit for the HMI M8 bolt holes; hole saws — 1-1/16 inch for the 3/4 inch cable gland and 3.5 inch for the HMI body hole; cable crimping tool and lug set sized to the cables used (4 AWG, 8 AWG, and 18 AWG); cable/wire cutters, zip ties, and electrical tape; multimeter (voltage/continuity); screwdrivers including a small flathead for the front-panel connector; wrenches and sockets; deburring tool; heat gun for heat-shrink; torque wrench suitable for the unit's terminal hardware; tape measure.

Provided components ship as loose kits. Core Power Unit (1 EA), Expansion Pack (optional, 1 EA), HMI Assembly (1 EA), and Height Plate P1007 (1 EA, 2 if Expansion is used).

K1001 Voltage Sense Wire kit: 18 AWG red wire, 12 ft. Used with K1002 in Section 6.11 (front panel sense wiring).

K1002 18 AWG Connection Kit (used by K1001 and K1004): 2x ring terminal 18-22AWG x 5/16, 1x butt splice 18-22AWG, 1x 2A spade ATC fuse, 1x 18 AWG fuse holder.

K1003 Tie Down Kit (2 kits provided, 3 if Expansion is used): tie-down bracket, 1/4-20 x 12 inch threaded rod, 2x nylon lock nut, 2x thin nut, 2x flat washer .25, 2x 10-32 x .3125 inch pan head screw, 2x flat washer No.10, 2x lock washer No.10.

K1004 HMI Power Wire kit: 20 ft of 18 AWG 2-conductor wire, 1x ring terminal 18-22AWG x 3/8.

K1005 Alternator Wire kit: 20 ft of 4 AWG red wire.

K1006 4 AWG Connection Kit: 1x ring terminal 4AWG x 3/8, 1x ring terminal 4AWG x 5/16, 1x 300A post fuse, 2x red 1/2 inch heat shrink.

K1007 HMI Communications kit: 1x CAN M12-5 elbow cable, 1x antenna, 1x 3/4 NPT cable gland.

Kit usage summary — K1001 + K1002 (Voltage Sense), used in front-panel sense wiring: 18 AWG red; crimp the 3/8 inch ring terminal (from K1004) at the alternator source; add the 2A inline fuse and holder from K1002 on the sense lead; butt-splice to extend if needed.

Kit usage summary — K1003 (Tie Down), used in mounting steps: 1/4-20 x 12 inch rod, flat washers, thin nut plus nylon lock nut, tie-down bracket, and 10-32 bracket screws/washers; used to mark, drill 9/32 inch holes, mount the brackets, and secure the unit.

Kit usage summary — K1004 + K1002 (HMI Power), used in HMI installation: 18 AWG 2-conductor; route to the battery box; crimp the 5/16 inch ring terminal (from K1002) and land on 48V POSITIVE / SYSTEM GROUND during Core Power installation.

Kit usage summary — K1005 + K1006 (Alternator), used in Core Power wiring: 4 AWG red; crimp a 3/8 inch ring to the 300A fuse post and a 5/16 inch ring to 12V POSITIVE; seal both lugs with the red 1/2 inch heat-shrink; 300A post fuse inline.

Kit usage summary — K1007 (HMI Communications), used in HMI installation: CAN cable with a 90-degree elbow to the Core Power front panel and a straight end to the HMI, plus antenna and 3/4 inch NPT cable gland.

Installer-supplied materials: sealant and touch-up paint for bare-metal cut/drill edges; heat-shrink tubing, cable ties, and loom/conduit per local code; any additional cable if a run exceeds the provided lengths.

As a general guideline, route each wire and cut it to length — leaving a service loop — before crimping its terminals. This avoids wasted cable and mis-cut leads. Seal high-current lugs with heat-shrink.

Didn't find what you needed?