IdleX Support

Contact Us

Troubleshooting the Core Power Unit

If a fault persists after the corrective action below, isolate the unit and contact support — do not open the enclosure or attempt internal repair.

Power & battery — Red fault LED flashing on battery: likely a fault in the battery string or a poor connection. Isolate loads, check power-post torque, press Reset/On, and inspect internal data connections per the service procedure.

Power & battery — Unit will not power on: likely the shipping disable is active. Confirm the Shipping Switch is enabled and press the 48V Power Button.

Power & battery — Loads drop offline at start-up: likely inverter inrush tripping battery protection. Use downstream pre-charge, wait the full pre-charge time, and follow the start-up sequence exactly.

Power & battery — No 12V output: likely a 12V supply path fault. Verify the 12V POSITIVE and SYSTEM GROUND connections, check converter status on the HMI, and verify voltage across the posts; if low, put it on a 12V charger.

Converter / charging — Converter not charging from alternator: likely a voltage-sense issue or shipping disable active. Confirm the ALTERNATOR VOLTAGE SENSE connection sees alternator voltage and verify the STARTER SYSTEM ENABLE / converter enable.

Converter / charging — No low-side voltage shown: likely the ALTERNATOR VOLTAGE SENSE is not connected. Verify the voltage-sense wire is connected to the alternator or 12V source.

Converter / charging — Unreasonable alternator temperature reading: likely a temp probe wiring error. Check the ALTERNATOR TEMP +/- wiring; the temp negative must join the harness, not chassis ground.

Converter / charging — No HMI / CAN data: likely a CAN wiring or termination issue. Confirm the CAN network connection and verify exactly two 120-ohm terminators (one built into the unit).

Engine starting — Engine will not crank: likely the Starter System is not charged or is OFF. Press the button (LED lights about 5 seconds if ON) and allow charging to complete (blinking stops).

Engine starting — LED not lighting: likely the module is OFF. Hold the button 5 seconds to switch it ON; the LED blinks while charging.

Engine starting — Arcing at the STARTER ONLY post: likely the wrong connection is on the post. Disconnect immediately, confirm only the starter solenoid is connected, and discharge before re-work per the safe-discharge procedure.

Didn't find what you needed?

Contact Support